درباره ما

VolPort، شرکت پیشرو در صنایع سنگ شکن و آسیاب چینی، در 30 سال گذشته همواره به توسعه سنگ شکن های سنگ معدن، ماشین آلات شن و ماسه سازی و آسیاب های صنعتی اختصاص داده شده است.

با ما تماس بگیرید

محصول

ما محصول

سنگ شکن موبایل

ما محصول

سنگ شکن فکی پیو

ما محصول

سنگ شکن VSI

Cracking the Secrets to Earthquake Safety, One Shake …

This video shows a simulation of seismic waves propagating throughout the San Francisco Bay area during and after a magnitude 7.0 earthquake at the Hayward fault, alongside a simulation of the movement and damage of an individual building in the region – a modern design, 40-story steel frame building.

Shake table testing of a physical model of telecomunication …

Results from resonance tests applied after the full-scale design earthquake test (test 33, Table 1) ... For design process of a telecommunication tower at the top of a mountain, experimental testing of a physical model on shake table was carried out. A test model of 7.03 m height was designed, built and tested at the Dynamic Testing Laboratory ...

Triaxial Earthquake and Shock Simulator > Engineer …

The Triaxial Earthquake and Shock Simulator (TESS), an experimental three-dimensional "shake table," tests the ability of systems, facilities, and equipment to survive under realistic conditions of shock, vibration, and earthquake ground motion., ... CERL engineers built a 1/20-scale model of the dam (the largest scale model of the dam ever to ...

Shake Table Studies on the Response of Scale Model …

The present study aims to experimentally investigate the performance of a scaled model framed structure placed on a well-designed GSI system comprising of sand-rubber mixture, using laboratory shake table studies. A 5-storey scaled model framed structure is placed on the GSI system in the middle of a sand bed inside a laminar shear box and ...

Shake Table I-40

The Quanser Shake Table I-40 is an open architecture bench-scale single-axis earthquake simulator ideal for teaching structural dynamics and control, …

Large Scale Geotechnical Shake Table Testing at the …

The shake table was used to excite the model with several motions, starting with sinusoidal excitation of 0.1 g and ending with simulated Kobe Earthquake (1995) Takatori record. The response of the bucket foundation was found to …

Engineers Shake Tallest Full-scale Building Ever …

Engineers gathered on May 9 to shake a 10-story mass timber building–the tallest full-scale building to be tested on an earthquake simulator. The test took place at the UC San Diego NSF-funded outdoor shake table, …

BENCH-SCALE SHAKE TABLES

This portable, bench-scale table moves along a single axis, however, two tables can be coupled for dual axis, x-y operation. The XY Shake Table III is a high-power system that can deliver …

State-of-the-art earthquake shake table model on display

State-of-the-art earthquake shake table model on display | University of Nevada, Reno

What Makes Shake Tables so Popular?

For some twenty years, Quanser Shake Tables are helping civil engineering students grasp complex concepts of structural dynamics and earthquake engineering more quickly and thoroughly. Engaging, hands-on experiments allow them to leap past dry theory and 'experience' an earthquake in safety of the lab. Inspired by Dr. Shirley Dyke, the driving force …

Shake It Up! Engineering for Seismic Waves

Well, engineers create shake tables to test the ability of buildings and other structures to withstand the seismic waves produced by earthquakes. To do this, they carefully design and construct shake tables that can accurately re …

Large-scale shake table testing of pile group-bridge model …

Large-scale shake table testing of pile group-bridge model in inclined liquefiable soils with overlying crusts. ... The failure mechanism of the pile group-bridge system under strong earthquakes is revealed. The results indicate that the lateral peak soil displacement profile has a linear distribution, while the lateral permanent displacement ...

MTS uses MATLAB & Simulink to validate seismic shake table …

MTS shake tables range in size from 1.5-by-1.5 meter, 2-ton tables that move along one axis for testing subscale models all the way up to 16-by-20 meter, 1,000-ton tables with six degrees of freedom for testing full-scale building models.

Teleoperation Tools for Bench-scale Shake Tables for …

Bench-scale shake tables are an engaging tool for educating students at all levels about the importance of earthquake engineering. Shake tables allow for classroom demonstrations and …

Post-earthquake damage assessments of unreinforced …

The natural ground motions for the shake table test were composed of: (i) acceleration record from Newhall - W Pico Canyon Rd. station during the 1994 Northridge Earthquake (PGA = 0.35 g), (ii) a record from the 1979 Coyote Lake Earthquake (PGA = 0.42 g), (iii) acceleration record from Parkfield - Fault Zone 1 station during the 2004 Parkfield ...

MOTORIZED SHAKE TABLE

MOTORIZED SHAKE TABLE Model an earthquake on a small scale! Build a simple structure on the shake table, start the motor, and watch the action! Will your building design survive the …

Experimental Shake Table Testing of an Adaptive Passive …

The implementation of a mechanical negative stiffness device (NSD) within a reduced-scale highway bridge model and its performance under seismic loading conditions is evaluated via shaking table tests. Four different isolation system configurations are considered: isolated bridge (IB), IB with viscous dampers, IB with NSDs, and IB with viscous dampers and …

1 g Shake Table Study on Seismic Behaviour of Model

Boulanger et al. mentioned key needs for advancing the design of pile foundations in soil profiles which are susceptible to liquefaction and lateral spreading during earthquakes. A series of large-scale dynamic centrifuge model tests were performed to study the behaviour of single piles and pile groups in a soil profile comprised of a non ...

JDR Vol.14 p.1154 (2019) | Fuji Technology Press: academic …

Problems in Earthquake Resistance Evaluation of Gabion Retaining Wall Based on Shake Table Test with Full-Scale Model Hiroshi Nakazawa *1,†, Kazuya Usukura *2, Tadashi Hara *3, Daisuke Suetsugu *4, Kentaro Kuribayashi *2, Tsuyoshi Nishi *5, Shun Kimura *6, and Shoji Shimomura *7 *1 Earthquake Disaster Mitigation Research Division, National Research …

Model testing using shake tables – current practice

The sophistication of shake tables has grown to allow the simulation of larger earthquakes and also the replication of movement in real earthquakes in all three dimensions. References Seible, F. & Shing, B. ( 1995 ) Worldwide Survey of …

Shake Table Tests: Seismic Soil-Pile-Superstructure Interaction

A series of shake table scale-model tests is being performed to provide insight into a variety of aspects of seismic soil-pile-superstructure interaction (SSPSI) and also to generate a data set with which to calibrate an advanced SSPSI numerical modeling tool presently being developed at UC Berkeley. ... a Loma Prieta earthquake Yerba Buena ...

Vision-aided nonlinear control framework for shake …

The structural response under the earthquake excitations can be simulated by scaled-down model shake table tests or full-scale model shake table tests. In this paper, adaptive control theory is used as a nonlinear shake table control algorithm ... In earthquake engineering, shake table control is an important issue. The main difficulty for the ...

Earthquake Shake Table

armature to shake platform (Fig. 14). Note the twist in the armature for strength. Step 3: Lock hex bolt in electric drill.-----Figures 15 and 16 show the final product. When using the shake table, secure it to the table it is resting on using clamps. This will prevent the shake table from walking when the drill is at high RPMs.

Development of 1-D Shake Table Testing Facility for

Shake table is an equipment which can be used for studying the dynamic response of structures during earthquakes. A typical shake table will have a base plate on which the structure or model can be placed and a mechanism for creating a desired shaking. ... Shake Table for Small Scale Dynamic Model Testing, Department of Civil Engineering ...

Tectonic hazards/Shake-table

Shake-table in earthquake engineering is a very effective experimental equipment to verify seismic performance associated with the direct damage to individual ... The earliest shake-table experiments were performed more than a century ago . A powerful shake table with a full scale building model on it. Wikimedia Commons has media related to ...

Testing Model Structures: Jell-O Earthquake in the Classroom …

Students make sense of the design challenges engineers face that arise from earthquake phenomena. Students work as engineering teams to explore concepts of how engineers design and construct buildings to withstand earthquake damage by applying elements of the engineering design process by building their own model structures using toothpicks and …

Shake table tests of steel moment resisting frame with …

A 1/4-scale MRF was built for the shake table tests with consideration of the limitations on the physical size and testing capacity of the shake table located at The Hong Kong Polytechnic University. The scaling process of the prototype frame followed the principles of similitude, as detailed in Table 2. The tested frame's story height and bay ...

The boundary conditions for simulations of a shake-table …

Boundary conditions can significantly affect a slope's behavior under strong earthquakes. To evaluate the importance of boundary conditions for finite element (FE) simulations of a shake-table experiment on the slope response, a validated three-dimensional (3D) nonlinear FE model is presented, and the numerical and experimental results are …

Seismic Response of a Cable-Stayed Bridge considering Non …

In the absence of intensive tests on the cable-stayed bridges under non-uniform excitation, this study provides a practical and accurate approach to investigate the seismic response of cable-stayed bridges considering spatially varying earthquake inputs. The cable-stayed bridge model with a scale ratio of 1:120 was designed and tested on a newly …

CONSTRUCTION AND PERFORMANCE TEST OF A LOW …

simulate a real earthquake completely, a shake table should have to be capable of moving in three reference directions. But, multicomponent shake tables are too expensive and require special knowledge and experience for construction and operation. Hence, smaller-sized, unidirectional tables are more suitable for the small-scale model analysis and